This overview is for designers, contractors and owners planning a sewage treatment plant in Oman. It summarises public sources, and the current official text must be checked before design.
This page summarises public sources and FUDESO product information. It is not legal advice; check current official texts before design or procurement.
The core regulation
- Ministerial Decision 145/1993 issues the Regulations on wastewater reuse and discharge. It is dated 13 June 1993 and was published in Official Gazette 506 on 3 July 1993 (FAOLEX via UNEP).
- It has been amended by Ministerial Decision 55/2002 (text) and Ministerial Decision 12/2017, dated 26 January 2017 (text).
- The limits are grouped into two classes, A-1 and A-2, according to the use of the treated water (tables below). The Environment Authority's licence process still requires analysis of the components set out in 145/1993 and its amendments.
Limits for treated wastewater: classes A-1 and A-2
The limits below come from the Technical Note on Water Quality Protection of the Duqm Special Economic Zone Authority (June 2018), Tables 2-7 and 2-8, which present the standards under Royal Decree 115/2001 and Ministerial Decision 145/1993 (source). It is a secondary summary, so confirm the current consolidated text with the Environment Authority before design.
Main parameters (mg/L unless stated)
| Parameter | Class A-1 | Class A-2 |
|---|---|---|
| BOD5 (5 days at 20°C) | 15 | 20 |
| COD | 150 | 200 |
| Suspended solids | 15 | 30 |
| Total dissolved solids | 1,500 | 2,000 |
| Electrical conductivity (µS/cm) | 2,000 | 2,700 |
| Sodium absorption ratio | 10 | 10 |
| pH | 6–9 | 6–9 |
| Ammoniacal nitrogen (as N) | 5 | 10 |
| Nitrate (as NO3) | 50 | 50 |
| Organic nitrogen | 5 | 10 |
| Phosphorus (total as P) | 30 | 30 |
| Oil and grease (total extractable) | 0.5 | 0.5 |
| Chloride (as Cl) | 650 | 650 |
| Sodium (as Na) | 200 | 300 |
| Phenols (total) | 0.001 | 0.002 |
| Sulphide (as S) | 0.1 | 0.1 |
| Faecal coliform bacteria (per 100 ml) | 200 | 1,000 |
| Viable nematode ova (per litre) | < 1 | < 1 |
Other substances (mg/L)
| Substance | Class A-1 | Class A-2 |
|---|---|---|
| Aluminium (as Al) | 5 | 5 |
| Arsenic (as As) | 0.1 | 0.1 |
| Barium (as Ba) | 1 | 2 |
| Beryllium (as Be) | 0.1 | 0.3 |
| Boron (as B) | 0.5 | 0.5 |
| Cadmium (as Cd) | 0.01 | 0.01 |
| Chromium (total as Cr) | 0.05 | 0.05 |
| Cobalt (as Co) | 0.05 | 0.05 |
| Copper (as Cu) | 0.5 | 1 |
| Cyanide (as Cn) | 0.05 | 0.1 |
| Fluoride (as F) | 1 | 2 |
| Iron (total as Fe) | 1 | 5 |
| Lead (as Pb) | 0.1 | 0.2 |
| Lithium (as Li) | 0.07 | 0.07 |
| Magnesium (as Mg) | 150 | 150 |
| Manganese (as Mn) | 0.1 | 0.5 |
| Mercury (as Hg) | 0.001 | 0.001 |
| Molybdenum (as Mo) | 0.01 | 0.05 |
| Nickel (as Ni) | 0.1 | 0.1 |
| Selenium (as Se) | 0.02 | 0.02 |
| Silver (as Ag) | 0.1 | 0.1 |
| Vanadium (as V) | 0.1 | 0.1 |
| Zinc (as Zn) | 5 | 5 |
Which class applies?
| Use | Class A-1 | Class A-2 |
|---|---|---|
| Grass and ornamental areas | Public parks; areas and lakes accessed by the public | Areas with no public access |
| Crops | Vegetables and fruits likely to be eaten raw within two weeks of irrigation | Vegetables to be cooked or processed; fruits not irrigated within two weeks of cropping; fodder, cereal and seed crops |
| Aquifer recharge | All recharge is controlled and monitored by the Ministry | All recharge is controlled and monitored by the Ministry |
| Methods of irrigation | Spray or other aerial irrigation is not permitted in areas with public access unless timing is controlled | Same rule |
| Any other reuse | Subject to prior approval | Subject to prior approval |
Ministerial Decision 12/2017, summarised in the same note, added the following to MD 145/93 and requires a separate permit or discharge licence for each: discharge of treated wastewater, produced water from oil production, reject water from desalination plants, wastewater to evaporation ponds, and a permit to discharge water (NOL). The note does not report any change to the limits above.
What the limits mean for plant design
- Meeting class A-1 for BOD5 (15 mg/L) and suspended solids (15 mg/L) usually calls for a tertiary step such as filtration or membranes, and disinfection is needed for the faecal coliform limit.
- Dissolved salts (TDS, conductivity, chloride, sodium) are not removed by biological treatment, so effluent salinity depends on the water supply and on any infiltration into the sewer or tank.
- State the target class in the tender or design brief; see the buyer's checklist.
Licence to discharge treated wastewater
| Item | Information from the Environment Authority service page |
|---|---|
| Service | License to Discharge (Treated Wastewater): discharging or reusing treated wastewater |
| Validity | Two years for new applications, renewable |
| Processing time | Ten working days, subject to complete documents and requirements |
| Prerequisite | An environmental permit |
Source: Environment Authority, Oman. The page does not say whether small package plants have a simplified route; confirm this with the Authority.
Practical sequence for plant design (our suggestion)
- Decide the end use of the treated water (discharge or a reuse category), because it determines the limits.
- Write the effluent class and the sampling points into the tender or design brief.
- Select a process (for example MBBR or MBR) that can hold the required quality with margin; see packaged STP options.
- Obtain the environmental permit, then apply for the discharge licence.
Context
Oman is expanding sewerage and treatment, and is also reusing more treated water. The Environment Authority surveyed 217 sewage and industrial wastewater treatment plants across the governorates over 2024–2025 (Times of Oman), which points to a growing focus on effluent quality.
Related: how to specify a packaged sewage treatment plant.