Industrial exhaust-gas standard QCVN 19:2024 and how to choose a treatment tower
ဖော်ပြသည် 21/11/2026ဤအကြောင်းအရာကို မဘာသာပြန်ရသေးပါ။ အင်္ဂလိပ်ဘာသာ ဗားရှင်းကို ပြထားပါသည်။
Industrial exhaust gas is controlled by QCVN 19:2024/BTNMT, a consolidated standard that replaces several earlier ones: QCVN 19:2009/BTNMT (dust and inorganic substances), QCVN 20:2009/BTNMT (some organic substances), QCVN 21:2009/BTNMT (chemical fertiliser), QCVN 22:2009/BTNMT (thermal power), QCVN 23:2009/BTNMT (cement), QCVN 34:2010/BTNMT (petrochemical refining, dust and inorganic part) and QCVN 51:2017/BTNMT (steel production).
Limits are split into three columns
- Column A: facilities located in a strictly protected zone.
- Column B: facilities located in an emission-restricted zone.
- Column C: facilities in neither case.
Values are in mg/Nm³, where 1 Nm³ is the volume of gas at 25°C and an absolute pressure of 760 mm Hg. Limits depend on the emitting equipment and the fuel; for example CO, SO₂ and NOx (as NO₂) have separate values for gas-, biomass-, liquid- and solid-fuel equipment and for waste incinerators.
Effective date and transition
- The standard was issued with Circular 45/2024/TT-BTNMT, signed on 30 December 2024 and effective from 1 July 2025.
- Facilities already operating, or projects with an approved EIA decision or a valid dossier accepted for EIA appraisal, environmental permit or environmental registration before 1 July 2025, may keep applying the earlier exhaust-gas standards for their type of activity and local regulations until the end of 31 December 2031.
- New projects, expansions or capacity increases filing after 1 July 2025 must apply QCVN 19:2024/BTNMT.
- From 1 January 2032 the facilities above must meet QCVN 19:2024/BTNMT, unless the provincial People’s Committee sets an earlier roadmap.
- The pollutants to be controlled are specified in the EIA decision or environmental permit by type of emission source; for technologies that generate new parameters not in the standard, limits follow the standards of a G7 country.
Volatile organic compounds (TVOC)
For paint, printing, glue and rubber plants, a key parameter is volatile organic compounds expressed as TVOC (including benzene, toluene, ethylbenzene, xylene, ethyl acetate and butyl acetate). Limits by equipment type:
| Emitting equipment | TVOC (mg/Nm³), Column A / B / C |
|---|---|
| Painting and surface coating (incl. drying and spraying) | 50 / 80 / 100 |
| Printing | 50 / 80 / 100 |
| Surface treatment, degreasing | 50 / 80 / 100 |
| Manufacture of paint, varnish, ink, glue | 80 / 120 / 150 |
| Rubber production | 80 / 100 / 150 |
| Waste incinerators | 30 / 40 / 50 |
How to choose an exhaust-gas treatment technology
- Identify the pollutants (dust, acid gases, solvent vapour, odour…), gas flow and inlet concentration by measurement.
- Check the limits in the facility’s EIA decision or environmental permit (Column A, B or C).
- Choose the equipment: a wet scrubber for acid gases and soluble dust; an activated-carbon adsorption tower for solvent vapour and organic compounds. When the carbon is saturated it must be replaced or regenerated.
- Post-treatment monitoring by a qualified organisation to demonstrate compliance.
See also exhaust gas treatment for factories: adsorption towers, scrubbers and other methods. Send your project information so FUDESO engineers can advise.
Download the regulation texts
- QCVN 19:2024/BTNMT (PDF, 675 KB)
- QCVN 30:2025/BNNMT (lò đốt chất thải) (PDF, 2.0 MB)
- QCVN 41:2025/BNNMT (đồng xử lý trong lò xi măng) (PDF, 901 KB)
See more documents in the regulation library.
Source: Circular 45/2024/TT-BTNMT and QCVN 19:2024/BTNMT, Official Gazette No. 151 + 152 of 24 January 2025 (Articles 2, 3 and 4 and Table 1). The article gives only some values and is for reference; detailed limits by equipment type, fuel and reference oxygen level must be checked against the official text and the facility’s environmental permit.
ဆက်စပ်အကြောင်းအရာများ
အကြံပေးဆွေးနွေးမှု တောင်းဆိုရန်
FUDESO အင်ဂျင်နီယာမှ ပြန်လည်ဆက်သွယ်၍ ဆွေးနွေးပြီး နေရာစစ်ဆေးရန် ရက်ချိန်းချမှတ်ပေးပါမည်။